Central heating problems


Central heating problems

Cold top section of radiator
This is usually an indication that air has got into the system somewhere and has become trapped. Air in a radiator will rise to the top forming a pocket stopping the hot water from getting to that part. This can be released, but remember to turn the heating off first. Now, armed with a rag beneath, use a radiator key to slacken the air bleed valve which is at one end towards the top of the radiator. There will be a hissing sound as the air comes out. As soon as water begins to flow, close the vent again and wipe away any water. Take care not to get scalded – the water may be pretty hot. The heating can then be switched back on.
Some systems have an automatic air release valve fitted. This usually has a small red top which should be slack to enable the air to escape
Radiators should not need frequent ‘bleeding’. If they do, air is getting in and this should be sorted out by a professional heating installer
Cold bottom section of radiator
This is a sign of rust and sludge build up which is sitting in the bottom of the radiator. Following the guides on removing and refitting a radiator, take the radiator outside and flush it through with a hosepipe. If you have the radiator standing on end, you should be able to flush out most of the sludge. Remember to carry the radiator upside down so you don't get sludge dripping on to your carpet.
With an open vent system, you may also consider using a proprietary heating system sludge remover. This will mean adding it to the feed and expansion tank and, a few days later, emptying and refilling the system. Follow the manufacturer’s instructions.
Upstairs radiators cold
This is most often an indication that the feed and expansion cistern in the loft has run dry. This should not happen and indicates another problem which needs to be sorted. It’s probable that the ball valve is not operating correctly. It may have jammed or be obstructed. Clear any obstruction or replace worn parts. Remember when refilling and adjusting the ball valve that there must be enough room for the water to expand when the system heats up. Therefore, when the system is cold, there should be just enough water to make the ball to float and switch off the water coming in.
Downstairs radiators cold
This is an indication that the pump has packed up. Have it tested and, if necessary, replaced.
All radiators cold or not very warm
This again is an indication of the build up of rust and sludge. See ‘Cold bottom section’ above.
Radiators cooler in one area of the house
This tells you that the radiators are not properly balanced. The nearest radiators to the boiler are taking more than their share of the hot water from the system. See page on balancing the system.
Warm radiators upstairs when the heating is off, and hot water is on
If this happens, it is probably because the check valve on a gravity fed system has failed. In a gravity fed system, the hot water cylinder is heated by water from the boiler which flows due to the gravity and not a pump. To prevent the water also heating the radiators when the heating is off, a check valve is fitted. If this has failed, the radiators upstairs will begin to receive some of the heat. The valve will need to be replaced by a heating engineer.
No heating or hot water
Make sure that the power supply is on and that a fuse hasn’t blown. Remember, if a fuse has blown, you should always rectify the cause first. As always, take great care with any electrical inspection or work. See electrics safety
Check that the gas or oil supply has not been turned off inadvertently. In the case of oil, check that you actually have some oil in the tank by reading the gauge
Check that the programmer is in the on position and that the thermostats are turned up high enough
Check that the pump is running. If not, get a heating engineer in to investigate.
Check that the pilot light is lit. If it isn't, follow the details for relighting in the boiler manual
If none of these solve the problem, it’s time to call in a heating engineer.
Feed and expansion tank overflowing
If the ball valve is not closing off the water supply properly, the cistern will continue to fill and water will come out from the overflow pipe. The usual cause is either a poorly adjusted valve or a worn washer. These can both be remedied in a similar fashion to the ball valve of the cold water storage tank.
For a large collection on boiler repair/service manuals please visit
http://www.gedi.co.uk/centralheating.html

Source: http://www.ArticlePros.com/author.php?george callender

More on Your Home and Appliances can be found below:

  • Why Honda Portable Generators Are Preferred During Emergencies
  • Select the Perfect Hot Tubs or Home Spa
  • Cool accessories for your Hot Tub
  • Coyote Spas offer an ideal means to relax and unwind
  • Installing Hot Tubs in the Right Way
  • Relax and Unwind in a Steam Shower Sauna
  • Shopping for air conditioners
  • Bose Lifestyle 38 Series IV-DVD Entertainment System
  • Bose Lifestyle 38 Series IV-Experience Music Like Never Before
  • Profiler season 1-4 32 dvd boxset
  • Choosing Laundry Dryers
  • Frigidaire Appliances
  • Disposables & Janitorial Supplies for Complete Restaurant Health
  • Cool and Healthy lifestyle - HVAC Installation
  • Spare Your Hands; Use Dishwashers


  • Central heating problems
  • Sizing a Gas Furnace and Central Air Conditioner for Your Home
  • A Look At The Different Types Of Heat Exchangers
  • Convection vs. Conventional Ovens... What's The Difference?
  • Window Air Conditioners - How To Reduce The Noise Level
  • Goodman Heat Pump
  • Eliminate Mildew Buildup in your Coffee Maker
  • Discount Toasters
  • The benefits of using a Hoover carpet cleaning machine
  • Portable carpet cleaning equipment benefits
  • What You Need To Know Before You Shop For A Microwave
  • Guide To Hot Tub Heaters
  • Tips on Getting the Right Vacuum Cleaner for your Needs!
  • Ovens. The right one for your kitchen.
  • Determining the portable generator that will deliver enough power

  •  

    Get this article to go

    RSS | JScript | Email | HTML

     

    About the author

    www.gedi.co.uk

    www.gedi.co.uk

     
    Email options
       

    ** Check all that apply **

     

    This article has been accessed 532 times since 2006-10-13.

    _________________